CHESTERLAND OH--November 14, 2011

CAS DataLoggers a short while ago offered the datalogging answer for the substantial company with plastic material normal water tanks. The client manufactured heavy cheap tanks, as thick being a business Pelican case, which is designed to mount throughout toilets. Normally a water system like a commode covered regarding 40-80 pounds connected with pressure, therefore the company ordinarily tried his or her toilets to help 2 or 3 periods that pertaining to safety reasons. However, a common plumbing contractor issue could create around the way of some sort of 'water hammer,' a new sudden raise in waters difficulty occurring if a valve abruptly closed at an end of your pipeline system, including when a properties occupants in the room made away a waters circulation originating from a dishwasher, a washing laundry machine, as well as a toilet. With the control device closed, the lake instantly was mandated to cease or change direction. Since the mass of waters was even now dan cing with excessive velocity, from the worst-case scenario, a mineral water sort could possibly surge the particular demand within the toilet's fish tank to the maximum amount of while 250lbs--enough for you to break open the serious nasty tank! To style actually much better containment constructions plus assist prevent virtually any perhaps damaging occurrences, the organization wanted to be able to calculate the number of pressure that may be generated within a reservoir explosion. These tanks have been commonly pressurised to help 40-70 PSI, nevertheless beneath specific mistake circumstances that demand could exceed 200 PSI, causing the fish tank to help strongly rupture. The company's challenging good quality warranty medical tests within the tanks recommended your strong yet handheld datalogging option supplying a large number with analog inputs, wireless Ethernet association to a PC or perhaps laptop, plus user-friendly configuration and display software.

The consumer installed a KineticSystems DAQ518 Portable High Speed Data Logger inside their testing spot in addition to linked them to be able to load cells put in in several lavatory tanks under analyze to history the actual force generated by sudden container ruptures. The DAQ518 was an entire 18-channel multiplexed transmission demanding fitness system showcasing sixteen differential reviews analog stations with permanent gain and also filters, 2 frequency inputs, along with a good external induce input. This lightweight procedure given 2 routes associated with primary tension gauge enter together with programmable excitation voltage, interior signal amplification as well as filtering, as well as the capacity to be able to history at around 50 kHz using an aggregate sampling price with approximately 32k samples/second. Using your data supplied because of the load cell phone manufacturer, personnel immediately set up the particular DAQ518 that will excite the particular fill cells, enhance this caused signal, and level the particular data to help force. Charts along with numeric units built into the application simplified the actual configuration of the actual experiment set-up simply by giving quick comments when adjustments were made.

For this safety tests, the software creator developed the test permanent fixture together with just one free walls to be able to comprise the tank. This free wall structure needed to possibly be instrumented usual approach concerning calculate the peak force produced in the event. Two compression "load button" place cells from Interface Technology had been chosen mainly because their particular small dimensions and also very low elevation authorized all of them to be without difficulty affixed concerning this no cost wall along with the fixed structure of the test out fixture. The load solar cells chosen experienced a distance regarding 0-500 lbs using a 150% overburden rating. Internally, your load cellular material made use of some sort of 4-wire link routine which needed a new voltage or current excitation in addition to given your moderate output with 2 mV/V connected with excitation along at the rated load. The tanks were then afflicted by intense mineral water sort e vents and the pressure regarding this resulting ruptures seemed to be recorded.

Another critical function on the DAQ518 datalogger had been its ability for you to bust huge facts models towards multiple, lesser documents intended for simpler manipulation in addition to analysis. Over the actual course with these tests, the actual heavy-duty tanks could receive anywhere you want to from several hours in order to many times that will flunk under stress. Consequently, facts had been sampled with 1 kHz in order to seize the actual maximum power made over the failure; this may perhaps generate greater than 3 hundred thousand points, building them not practical to try in order to examine this kind of considerably records in a very individual file. By stopping the info into many smaller files, it turned out way quicker along with a lot easier with regard to entrepreneurs that will lens on the part of interest.

The DAQ518 datalogger comprised a rugged, portable stand-alone information logging system with as long as 64 channels, detachable Flash recollection in addition to Ethernet speaking for commercial plus in-vehicle applications. Auto-configuration on power-up has been reinforced for stand-alone applications. The ultra-compact plus thoroughly enclosed chassis acessed only 2.5lbs (1.13kg), so that it is a perfect transportable solution. The logger highlighted a couple of analog source channels together with link transmission conditioning, programmable attain and filter, together with of sixteen analog input programmes together with fixed gain and also filter. The datalogger likewise presented an outside trigger feedback along with 2 further volume way of measuring channels, 16-bit analog-to-digital converter resolution, as well as a maximum aggregate sampling quote of 50 kHz. Local CompactFlash records safe-keeping was furthermore standard. 10BaseT Ethernet connectivity to be able to a PC or even laptop empowered cell verbal exchanges when using the data logger for setup, information display plus processing.

VersaDAQ computer software seemed to be included zero cost while using info logger and maintained as well as managed this datalogger's operations like setup, data acquisition, along with facts recording. VersaDAQ ran using a PC or maybe laptop computer and also attached to the datalogger's chassis via the 10Base T Ethernet connection. The software's user-friendly interface granted fast setup with regard to facts group and also storage, as well as configured channels, sample rate, history manner plus calibration.

The plastic tank supplier benefitted in several major ways following assembly of the DAQ518 Portable High Speed Datalogger for their level of quality warranty testing, main that has been the ability that will properly file the induce from the restricted explosions, specifically producing a less dangerous plus much more reputable product. The datalogger made available testers the two portability and cell Ethernet connection, making logging handy in addition to hassle-free. Additionally, the particular involved computer software seemed to be effortless to read and also easily controlled this logger's countless setup, configuration and saving functions.

For further more information for the KineticSystems DAQ518 18-Channel Portable High Speed Datalogger, other KineticSystems portable info purchase in addition to datalogging systems, in order to get the ideal answer for the application-specific needs, contact a CAS Data Logger Applications Specialist with (800) 956-4437 or even visit the particular internet site during

Contact Information: CAS DataLoggers, Inc. 12628 Chillicothe Road Chesterland, Ohio 44026 (440) 729-2570 (800) ://